Each block encodes a specific option in the Mass-EXPERT flow meter model code. All 23 tables with codes, descriptions and notes are provided below.
Back to modifications
| Code | DN | Max. flow rate, kg/min | Max. flow rate, kg/h |
|---|---|---|---|
| 001 | DN01 | 0.2 | 12 |
| 002 | DN02 | 1.6 | 96 |
| 003 | DN03 | 3 | 180 |
| 004 | DN04 | 5 | 300 |
| 008 | DN08 | 20 | 1 200 |
| 015 | DN15 | 60 | 3 600 |
| 020 | DN20 | 100 | 6 000 |
| 025 | DN25 | 200 | 12 000 |
| 040 | DN40 | 450 | 27 000 |
| 050 | DN50 | 650 | 39 000 |
| 080 | DN80 | 2 000 | 120 000 |
| 100 | DN100 | 3 000 | 180 000 |
| 150 | DN150 | 12 000 | 720 000 |
| 200 | DN200 | 18 000 | 1 080 000 |
| 250 | DN250 | 29 000 | 1 740 000 |
| Code | Description | Note |
|---|---|---|
| T | Standard version | −50…+150 °C, P≤10 MPa |
| P | Elevated pressure | −50…+150 °C, >10 MPa; ≤45 MPa depending on size (operation manual, Table 2.1) |
| L | Cryogenic design | −196…+150 °C, U/Δ models only |
| D | Ultra-low temperatures | −255…+150 °C, remote design only; below −196 °C, measurement is outside the type approval scope — subject to separate agreement |
| G | High temperature | −50…+230 °C; remote design — available, with some exceptions (operation manual 2.2.5) |
| C | Ultra-high temperature | −50…+350 °C, remote design only |
| X | Special operating conditions | detailed description required |
| Code | Description | Note |
|---|---|---|
| U | U-shaped measuring tube type | for ≥ DN03 only |
| K | Wide U-shaped measuring tube type | DN02–DN25 only |
| W | Micro-bend measuring tubes | |
| L | Straight-tube | |
| D | Triangular Δ-type measuring tubes | DN01, DN02, DN25 only |
| X | Special version | description required |
| Code | Pressure, MPa | Note |
|---|---|---|
| 02 | 1.6 | |
| 04 | 4 | by default: flange, min. class 4 MPa |
| 06 | 6.3 | |
| 10 | 10 | |
| 16 | 16 | |
| 20 | 20 | |
| 25 | 25 | |
| 30 | 30 | |
| 35 | 35 | |
| 40 | 40 | |
| 45 | 45 | |
| 70 | 70 | |
| 90 | 90 | |
| XX | Special | description required |
| Code | Standard | Note |
|---|---|---|
| RXXXYYYZ | GOST 33259 | XXX-DN, mm; YYY-PN, kgf/cm²; Z-version |
| ENXXXYYYZ | EN 1092-1 | XXX-DN, mm; YYY-PN, bar; Z-version |
| ASXXYYYYZZZ | ASME B16.5 | XX-DN, inch; YYYY-Class; ZZZ-version |
| FR | HG/T 20592-2009 WN RF PN16 | DN10–DN300 |
| FQ | HG/T 20592-2009 WN RF PN25 | DN10–DN300 |
| FT | HG/T 20592-2009 WN RF PN40 | DN10–DN300 |
| FU | HG/T 20592-2009 WN RF PN63 | DN10–DN300 |
| FV | HG/T 20592-2009 WN RF PN100 | DN10–DN300 |
| FW | HG/T 20592-2009 WN RF PN160 | DN10–DN300 |
| FA | HG/T 20615-2009 WN RF Class150 | DN15–DN300 |
| FB | HG/T 20615-2009 WN RF Class300 | DN15–DN300 |
| FC | HG/T 20615-2009 WN RF Class600 | DN15–DN300 |
| FD | HG/T 20615-2009 WN RF Class900 | DN15–DN300 |
| FE | HG/T 20615-2009 WN RF Class1500 | DN15–DN300 |
| GS | G thread | pipe thread |
| G4 | G1/4" thread | pipe thread |
| G2 | G1/2" thread | pipe thread |
| G1 | G1" thread | pipe thread |
| DS | DIN 11851-SI | mm |
| DT | DIN 11851-US | inches |
| DU | DIN 11864-1 Form A, threaded | sanitary |
| DV | DIN 11864-2 Form A, flat flange | |
| GT | GB/T 9115-2010 RF PN25 | DN10–DN300 |
| GU | GB/T 9115-2010 RF PN16 | DN10–DN300 |
| GV | GB/T 9115-2010 RF PN40 | DN10–DN300 |
| GW | GB/T 9115-2010 RF PN63 | DN10–DN300 |
| GX | GB/T 9115-2010 RF PN100 | DN10–DN300 |
| GY | GB/T 9115-2010 RF PN160 | DN10–DN300 |
| US | UNF thread | tapered |
| UA | UNF thread 9/16-18UNF | tapered |
| UB | UNF thread 1 3/8-12UNF | tapered |
| RC | RC thread | |
| RD | Rc 3/4" thread | |
| HS | Tri-clamp DN32676:2022-10 | ∅25 |
| HA | Tri-clamp DN32676:2022-10 | ∅34 |
| HB | Tri-clamp DN32676:2022-10 | ∅50.5 |
| HC | Tri-clamp DN32676:2022-10 | ∅64 |
| HD | Tri-clamp DN32676:2022-10 | ∅91 |
| AS | ASME B16.5-2020, weld-neck Class 150 | 1/2–12" |
| AT | ASME B16.5-2020 Class 300 | 1/2–12" |
| AU | ASME B16.5-2020 Class 600 | 1/2–12" |
| AV | ASME B16.5-2020 Class 900 | 1/2–12" |
| AW | ASME B16.5-2020 Class 1500 | 1/2–12" |
| AX | ASME B16.5-2020 Class 2500 | 1/2–12" |
| GA | GOST 12821-80, 1.6 MPa | DN10–DN300 |
| GB | GOST 12821-80, 2.5 MPa | DN10–DN300 |
| GC | GOST 12821-80, 4 MPa | DN10–DN300 |
| GD | GOST 12821-80, 6.3 MPa | DN10–DN300 |
| GE | GOST 12821-80, 10 MPa | DN10–DN300 |
| GF | GOST 12821-80, 16 MPa | DN15–DN300 |
| GG | GOST 12821-80, 20 MPa | DN15–DN300 |
| GH | GOST 33259-2015 PN16-B | DN15–DN300 |
| GJ | GOST 33259-2015 PN25-B | DN15–DN300 |
| GK | GOST 33259-2015 PN40-B | DN15–DN300 |
| GL | GOST 33259-2015 PN63-B | DN15–DN300 |
| GM | GOST 33259-2015 PN100-B | DN15–DN300 |
| GN | GOST 33259-2015 PN160-B | DN15–DN300 |
| ES | EN 1092-1:2007(E) Type11 PN16 | DN10–DN300 |
| ET | EN 1092-1:2007(E) Type11 PN25 | DN10–DN300 |
| EU | EN 1092-1:2007(E) Type11 PN40 | DN10–DN300 |
| EV | EN 1092-1:2007(E) Type11 PN63 | DN10–DN300 |
| EW | EN 1092-1:2007(E) Type11 PN100 | DN10–DN300 |
| EX | EN 1092-1:2007(E) Type11 PN160 | DN10–DN300 |
| JS | JIS B2220:2004 RF 10K | DN10–DN300 |
| JT | JIS B2220:2004 RF 20K | DN10–DN300 |
| JU | JIS B2220:2004 RF 40K | DN10–DN300 |
| JV | JIS B2220:2004 RF 63K | DN10–DN300 |
| SS | SMS 1145, threaded | sanitary |
| MS | Metal seal | |
| OS | O-Ring seal | |
| ZS | ZG1/8-F | |
| ZT | ZG1/2-F | |
| ZU | ZG3/4-F | |
| ZV | ZG1-F | |
| NR | 1/4" NPT-F | |
| NS | 1/2" NPT-F | |
| NT | 3/4" NPT-F | |
| NU | 1" NPT-F | |
| BS | 1/2" flange | |
| VS | VCO connection | |
| VA | VCO connection | VCO1/2" |
| VB | VCO connection | VCO3/4" |
| VC | VCO connection | VCO1" |
| VR | VCR connection | VCR1/8" |
| VT | VCR connection | VCR1/4" |
| VU | VCR connection | VCR1/2" |
| VV | VCR connection | VCR3/4" |
| VW | VCR connection | VCR1" |
| KT | Union nut (cartridge connection) | |
| C8 | Process connection type change only | description required: only the flange or thread changes; the sensor body remains unchanged |
| C9 | Special connection | description required |
| Code | Material | Note |
|---|---|---|
| S | 316L | default |
| G | 316L with high nickel content | |
| L | 904L | |
| T | Titanium | |
| C | C4 steel | |
| H | Hastelloy | |
| D | Duplex steel | |
| A | Tantalum | |
| X | Other materials | description required |
| Code | Description | Note |
|---|---|---|
| S | 0.1% | mass |
| A | 0.15% | mass |
| B | 0.2% | mass |
| C | 0.5% | mass |
| D | 1.0% | mass |
| X | Other requirements | description required |
| Code | Description | Note |
|---|---|---|
| N | Integrated design | |
| S | Remote (separate) design | default cable length — 3 m |
| J | Compact integrated design | without explosion protection |
| D | DIN-rail mounting | without explosion protection |
| X | Other requirements | detailed description required |
| Code | Description | Note |
|---|---|---|
| C | With display | |
| M | Without display | default |
| X | Other requirements | description required |
| Code | Description | Note |
|---|---|---|
| M | Modbus RTU/RS-485, active pulse | default |
| L | 4-20 mA active + default signals | |
| H | HART + 4-20 mA active + default signals | |
| P | Modbus RTU/RS-485, active pulse | in addition to the main signals (code "P" = "+ Modbus…" per the operation manual) |
| X | Other requirements | description required |
Output set per the type approval description: 4–20 mA (incl. HART), frequency-pulse 0–10,000 Hz, RS-485 (Modbus RTU), CAN; PROFIBUS PA is an option; availability depends on the version (type approval description, block 10J).
| Code | Description | Note |
|---|---|---|
| N | None | default |
| C | Ex explosion protection | |
| A | Design to 3-A requirements | |
| S | TS special equipment manufacturing license | |
| J | CCS classification society certificate | |
| X | Other requirements | description required |
| Code | Version | Note |
|---|---|---|
| V1 | ME100 | default |
| V2 | ME200 | |
| V3 | ME300 | |
| V4 | ME400 | ultra-compact, stainless steel, without display |
| XX | Special version | description required |
| Code | Mode | Note |
|---|---|---|
| M | Mass | default |
| D | Density | |
| A | Mass and density | |
| X | Other requirements | description required |
| Code | Material | Note |
|---|---|---|
| E | 304 | |
| S | 316L | default |
| G | 316L with high nickel content | |
| L | 904L | |
| T | Titanium | |
| C | C4 steel | |
| H | Hastelloy | |
| D | Duplex steel | |
| A | Tantalum | |
| X | Other materials | description required |
| Code | Material | Note |
|---|---|---|
| E | 304 | |
| S | 316L | |
| X | Other materials | description required |
| Code | Power | Note |
|---|---|---|
| 1 | 24 V DC | default |
| 2 | 220 V AC / 24 V DC | automatic |
| X | Other requirements | description required |
| Code | Type | Note |
|---|---|---|
| N | 1/2" NPT | |
| M | M20×1.5 | default |
| X | Special version | description required |
| Code | Accuracy, kg/m³ | Note |
|---|---|---|
| 1 | 3 | |
| 2 | 1 | |
| 3 | 0.5 | |
| 4 | 0.2 | |
| 5 | 0.15 | |
| Q | No requirements | default |
| Code | Description | Note |
|---|---|---|
| N | None | default |
| Y | Yes | (learn more) |
| Code | Language | Note |
|---|---|---|
| E | English | |
| C | Chinese | |
| R | Russian | default |
| X | Other | description required |
| Code | Description | Note |
|---|---|---|
| 0 | None | default |
| 1 | Mating carbon steel flanges, fasteners, spiral-wound gaskets | |
| 2 | Mating stainless steel flanges, fasteners, spiral-wound gaskets | |
| X | Other | description required |
| Code | Description | |
|---|---|---|
| N | None | default |
| ETOZZZ | ZZZ — alphanumeric designation. May not be shown on the nameplate; it is linked to the serial number. Used for custom solutions tailored to unique requirements through engineering and design work. |
| Code | Description | Note |
|---|---|---|
| - | Standard: 18 months from the delivery date or 12 months after installation — whichever comes first (operation manual, clause 5.3) | default |
| EW | Extended: 24 months from commissioning, but not more than 36 months from the date of manufacture | |
| SW | Special — specific warranty terms. Specified separately |
We will contact you shortly.