Specification

Full configuration table

23 option blocks — designation structure

Each block encodes a specific option in the Mass-EXPERT flow meter model code. All 23 tables with codes, descriptions and notes are provided below.

Back to modifications
Model code designation structure

1A | Nominal diameter

CodeDNMax. flow rate, kg/minMax. flow rate, kg/h
001DN010.212
002DN021.696
003DN033180
004DN045300
008DN08201 200
015DN15603 600
020DN201006 000
025DN2520012 000
040DN4045027 000
050DN5065039 000
080DN802 000120 000
100DN1003 000180 000
150DN15012 000720 000
200DN20018 0001 080 000
250DN25029 0001 740 000

2B | Standard operating conditions

CodeDescriptionNote
TStandard version−50…+150 °C, P≤10 MPa
PElevated pressure−50…+150 °C, >10 MPa; ≤45 MPa depending on size (operation manual, Table 2.1)
LCryogenic design−196…+150 °C, U/Δ models only
DUltra-low temperatures−255…+150 °C, remote design only; below −196 °C, measurement is outside the type approval scope — subject to separate agreement
GHigh temperature−50…+230 °C; remote design — available, with some exceptions (operation manual 2.2.5)
CUltra-high temperature−50…+350 °C, remote design only
XSpecial operating conditionsdetailed description required

3C | Sensor type

CodeDescriptionNote
UU-shaped measuring tube typefor ≥ DN03 only
KWide U-shaped measuring tube typeDN02–DN25 only
WMicro-bend measuring tubes
LStraight-tube
DTriangular Δ-type measuring tubesDN01, DN02, DN25 only
XSpecial versiondescription required

4D | Maximum working pressure

CodePressure, MPaNote
021.6
044by default: flange, min. class 4 MPa
066.3
1010
1616
2020
2525
3030
3535
4040
4545
7070
9090
XXSpecialdescription required

5E | Process connection

CodeStandardNote
RXXXYYYZGOST 33259XXX-DN, mm; YYY-PN, kgf/cm²; Z-version
ENXXXYYYZEN 1092-1XXX-DN, mm; YYY-PN, bar; Z-version
ASXXYYYYZZZASME B16.5XX-DN, inch; YYYY-Class; ZZZ-version
FRHG/T 20592-2009 WN RF PN16DN10–DN300
FQHG/T 20592-2009 WN RF PN25DN10–DN300
FTHG/T 20592-2009 WN RF PN40DN10–DN300
FUHG/T 20592-2009 WN RF PN63DN10–DN300
FVHG/T 20592-2009 WN RF PN100DN10–DN300
FWHG/T 20592-2009 WN RF PN160DN10–DN300
FAHG/T 20615-2009 WN RF Class150DN15–DN300
FBHG/T 20615-2009 WN RF Class300DN15–DN300
FCHG/T 20615-2009 WN RF Class600DN15–DN300
FDHG/T 20615-2009 WN RF Class900DN15–DN300
FEHG/T 20615-2009 WN RF Class1500DN15–DN300
GSG threadpipe thread
G4G1/4" threadpipe thread
G2G1/2" threadpipe thread
G1G1" threadpipe thread
DSDIN 11851-SImm
DTDIN 11851-USinches
DUDIN 11864-1 Form A, threadedsanitary
DVDIN 11864-2 Form A, flat flange
GTGB/T 9115-2010 RF PN25DN10–DN300
GUGB/T 9115-2010 RF PN16DN10–DN300
GVGB/T 9115-2010 RF PN40DN10–DN300
GWGB/T 9115-2010 RF PN63DN10–DN300
GXGB/T 9115-2010 RF PN100DN10–DN300
GYGB/T 9115-2010 RF PN160DN10–DN300
USUNF threadtapered
UAUNF thread 9/16-18UNFtapered
UBUNF thread 1 3/8-12UNFtapered
RCRC thread
RDRc 3/4" thread
HSTri-clamp DN32676:2022-10∅25
HATri-clamp DN32676:2022-10∅34
HBTri-clamp DN32676:2022-10∅50.5
HCTri-clamp DN32676:2022-10∅64
HDTri-clamp DN32676:2022-10∅91
ASASME B16.5-2020, weld-neck Class 1501/2–12"
ATASME B16.5-2020 Class 3001/2–12"
AUASME B16.5-2020 Class 6001/2–12"
AVASME B16.5-2020 Class 9001/2–12"
AWASME B16.5-2020 Class 15001/2–12"
AXASME B16.5-2020 Class 25001/2–12"
GAGOST 12821-80, 1.6 MPaDN10–DN300
GBGOST 12821-80, 2.5 MPaDN10–DN300
GCGOST 12821-80, 4 MPaDN10–DN300
GDGOST 12821-80, 6.3 MPaDN10–DN300
GEGOST 12821-80, 10 MPaDN10–DN300
GFGOST 12821-80, 16 MPaDN15–DN300
GGGOST 12821-80, 20 MPaDN15–DN300
GHGOST 33259-2015 PN16-BDN15–DN300
GJGOST 33259-2015 PN25-BDN15–DN300
GKGOST 33259-2015 PN40-BDN15–DN300
GLGOST 33259-2015 PN63-BDN15–DN300
GMGOST 33259-2015 PN100-BDN15–DN300
GNGOST 33259-2015 PN160-BDN15–DN300
ESEN 1092-1:2007(E) Type11 PN16DN10–DN300
ETEN 1092-1:2007(E) Type11 PN25DN10–DN300
EUEN 1092-1:2007(E) Type11 PN40DN10–DN300
EVEN 1092-1:2007(E) Type11 PN63DN10–DN300
EWEN 1092-1:2007(E) Type11 PN100DN10–DN300
EXEN 1092-1:2007(E) Type11 PN160DN10–DN300
JSJIS B2220:2004 RF 10KDN10–DN300
JTJIS B2220:2004 RF 20KDN10–DN300
JUJIS B2220:2004 RF 40KDN10–DN300
JVJIS B2220:2004 RF 63KDN10–DN300
SSSMS 1145, threadedsanitary
MSMetal seal
OSO-Ring seal
ZSZG1/8-F
ZTZG1/2-F
ZUZG3/4-F
ZVZG1-F
NR1/4" NPT-F
NS1/2" NPT-F
NT3/4" NPT-F
NU1" NPT-F
BS1/2" flange
VSVCO connection
VAVCO connectionVCO1/2"
VBVCO connectionVCO3/4"
VCVCO connectionVCO1"
VRVCR connectionVCR1/8"
VTVCR connectionVCR1/4"
VUVCR connectionVCR1/2"
VVVCR connectionVCR3/4"
VWVCR connectionVCR1"
KTUnion nut (cartridge connection)
C8Process connection type change onlydescription required: only the flange or thread changes; the sensor body remains unchanged
C9Special connectiondescription required

6F | Measuring tube material

CodeMaterialNote
S316Ldefault
G316L with high nickel content
L904L
TTitanium
CC4 steel
HHastelloy
DDuplex steel
ATantalum
XOther materialsdescription required

7G | Accuracy

CodeDescriptionNote
S0.1%mass
A0.15%mass
B0.2%mass
C0.5%mass
D1.0%mass
XOther requirementsdescription required

8H | Transmitter mounting type

CodeDescriptionNote
NIntegrated design
SRemote (separate) designdefault cable length — 3 m
JCompact integrated designwithout explosion protection
DDIN-rail mountingwithout explosion protection
XOther requirementsdetailed description required

9I | Display

CodeDescriptionNote
CWith display
MWithout displaydefault
XOther requirementsdescription required

10J | Output signals

CodeDescriptionNote
MModbus RTU/RS-485, active pulsedefault
L4-20 mA active + default signals
HHART + 4-20 mA active + default signals
PModbus RTU/RS-485, active pulsein addition to the main signals (code "P" = "+ Modbus…" per the operation manual)
XOther requirementsdescription required

Output set per the type approval description: 4–20 mA (incl. HART), frequency-pulse 0–10,000 Hz, RS-485 (Modbus RTU), CAN; PROFIBUS PA is an option; availability depends on the version (type approval description, block 10J).

11K | Certification

CodeDescriptionNote
NNonedefault
CEx explosion protection
ADesign to 3-A requirements
STS special equipment manufacturing license
JCCS classification society certificate
XOther requirementsdescription required

12L | Transmitter version

CodeVersionNote
V1ME100default
V2ME200
V3ME300
V4ME400ultra-compact, stainless steel, without display
XXSpecial versiondescription required

13M | Measurement mode

CodeModeNote
MMassdefault
DDensity
AMass and density
XOther requirementsdescription required

14N | Process connection material

CodeMaterialNote
E304
S316Ldefault
G316L with high nickel content
L904L
TTitanium
CC4 steel
HHastelloy
DDuplex steel
ATantalum
XOther materialsdescription required

15O | Sensor housing material

CodeMaterialNote
E304
S316L
XOther materialsdescription required

16P | Power supply

CodePowerNote
124 V DCdefault
2220 V AC / 24 V DCautomatic
XOther requirementsdescription required

17Q | Cable entry

CodeTypeNote
N1/2" NPT
MM20×1.5default
XSpecial versiondescription required

18R | Density measurement

CodeAccuracy, kg/m³Note
13
21
30.5
40.2
50.15
QNo requirementsdefault

19S | Isothermal jacket

CodeDescriptionNote
NNonedefault
YYes(learn more)

20T | Interface language

CodeLanguageNote
EEnglish
CChinese
RRussiandefault
XOtherdescription required

21U | Additional scope of supply

CodeDescriptionNote
0Nonedefault
1Mating carbon steel flanges, fasteners, spiral-wound gaskets
2Mating stainless steel flanges, fasteners, spiral-wound gaskets
XOtherdescription required

22V | Additional ETO options — on request

CodeDescription
NNonedefault
ETOZZZZZZ — alphanumeric designation. May not be shown on the nameplate; it is linked to the serial number. Used for custom solutions tailored to unique requirements through engineering and design work.

23X | Warranty terms

CodeDescriptionNote
-Standard: 18 months from the delivery date or 12 months after installation — whichever comes first (operation manual, clause 5.3)default
EWExtended: 24 months from commissioning, but not more than 36 months from the date of manufacture
SWSpecial — specific warranty terms. Specified separately
Back to modifications Home
Наверх