Industry application

Coriolis flow meters for biotechnology

Precision dosing for fermentation and cultivation

Mass flow meters Mass-EXPERT for high-accuracy dosing of nutrient media, pH adjusters and antifoams in fermentation and cell culture processes. Ultra-low flow rates (fractions of kg/h) — D-type (Δ) DN01–DN02. Full SIP compatibility, 3-A hygienic design with Ra ≤ 0.8 µm surface roughness guarantee sterility and cleanliness in demanding biotechnological processes.

Recommended configurations Request a quote
Fermentation Micro-flow DN01–DN02 SIP compatibility 3-A hygienic design Ra ≤ 0.8 µm
Typical media

Measurement of biotechnological media

Mass-EXPERT Coriolis flow meters provide high-accuracy measurement and dosing of a wide range of biotechnological liquids — from sterile nutrient media to aggressive pH adjusters and antifoams.

Nutrient media

Dosing of sterile nutrient media for fermentation, cell culture and microbiological processes. The accuracy of volumetric dosing is critical for biomass growth and target product yield.

LB broth SOC medium RPMI-1640 DMEM

pH adjusters

Dosing of acids and alkalis to maintain pH within a specified range during fermentation. Ultra-low flow rates (fractions of kg/h) require D-type DN01–DN02 sensors with maximum sensitivity.

HCl H₂SO₄ NaOH KOH

Antifoams

Automatic supply of antifoams (Antifoam) based on the foam sensor signal to prevent fermenter overflow. Micro-pulse dosing — an ideal task for small-diameter Δ-shaped sensors.

Silicone AF Pluronic PPG SAG series

Substrates and precursors

Addition of solutions of glucose, lactose, amino acids, vitamin supplements and target precursors during fermentation. Control of every microliter is the key to reproducibility and quality of the bioproduct.

Glucose Lactose Amino acids Vitamins

Sterility standards and hygiene requirements

Biotechnological manufacturing places the highest demands on sterility, sanitation and traceability. Mass-EXPERT complies with key industry standards and regulations.

SIP compatibility
The sensors withstand steam-in-place (Steam-in-Place) sterilization without dismantling.
3-A hygienic design
L-type (straight-tube) sensors with smooth surfaces and no dead zones ensure complete drainage. The hygienic design is engineered to 3-A Sanitary Standards requirements. For Russia, Expert Conclusion No. 299 on compliance with the Common Requirements of the Customs Union is available.
Ra ≤ 0.8 µm
Mirror polishing of contact surfaces prevents adhesion of microorganisms and facilitates CIP/SIP cleaning.
Tri-clamp connections
Hygienic clamp connections for quick installation, dismantling and sterilization without special tools.
Advantages

Why Mass-EXPERT for biotechnology?

Coriolis direct mass measurement technology — the ideal solution for precision biotechnological processes where the cost of an error is the loss of the target product

Micro-flow D-type (Δ) DN01–DN02

Specialized Δ-shaped sensors for flow rates from fractions of kg/h. Ideal for dosing pH adjusters, antifoams and micronutrients in laboratory and pilot fermenters.

Full SIP compatibility

The sensors withstand multiple steam sterilization cycles without loss of metrological characteristics. The dead-zone-free design eliminates the risk of contamination.

3-A hygienic design

L-type straight-tube sensors, U- and W-type sensors or D-type Δ-shaped sensors in hygienic design with mirror polishing Ra ≤ 0.8 µm ensure uncompromising cleanliness.

Ultra-high accuracy from 0.1%

Dosing with accuracy up to 0.1% of flow rate ensures strict adherence to the recipe and maximum biomass yield. Excess consumption of nutrient medium or adjuster means direct losses.

Independence from medium properties

Coriolis measurement determines mass directly rather than volume. Density, viscosity, gas evolution or suspended solids do not distort the result — critical for foaming and heterogeneous media.

Tri-clamp connections

Medical-grade Tri-clamp connections — the biotech equipment standard. Quick installation and removal, full sterilization as assembled, no threaded crevices.

Δ-shaped D-type — a specialized solution for micro-flow

In biotechnological processes, dosing accuracy for small amounts of reagents is critical. Δ-shaped D-type sensors DN01–DN02 are specifically designed for measuring ultra-low mass flow rates — from fractions to units of kg/h. The compact Δ-shaped tube configuration provides maximum sensitivity with minimal internal volume, while the hygienic design with Tri-clamp connections allows the sensor to be integrated directly into the sterile loop of a fermenter or bioreactor without additional adapters.

Recommended configurations

Optimal solutions for biotechnology

Proven combinations of sensors, materials and options for typical tasks of biotech production facilities and laboratories

D-type (Δ) for micro-flow

Specialized Δ-shaped sensor for ultra-low flow rates — the heart of precision dosing in biotechnology.

  • Range: fractions of kg/h – a few kg/h
  • DN01–DN02 — minimal volume
  • Δ-shaped configuration — max. sensitivity
  • Full SIP compatibility

L-type — straight measuring tubes

Straight-tube sensors without bends — the hygienic design standard for sterile media.

  • Complete drainage — no dead zones
  • efficient CIP/SIP cleaning
  • Minimal hydraulic resistance
  • DN08–DN25 for typical flow rates

Tri-clamp hygienic connections

The biotechnology connection standard — Tri-clamp fittings for sterile loops.

  • Tri-clamp — the universal hygienic standard
  • Sterilization without disassembly
  • Quick-release — no special tools required
  • Thread-free design — no crevices

Mirror polishing Ra ≤ 0.8 µm

Surface finish class for contact with sterile biotechnological media.

  • Ra ≤ 0.8 µm — the biotechnology standard
  • Optional Ra ≤ 0.4 µm
  • Electropolishing — passive layer
  • Surface finish certification

ME100 transmitter

Reliable and compact electronic unit for integration into bioreactor control systems. Available versions: ME200 — 220 V power supply, ME300 — cabinet-mounted DIN-rail transmitter, ME400 — ultra-compact version.

  • 4–20 mA HART, Modbus RTU
  • Integration with bioreactor SCADA
  • Flow and dose display
  • Settings protection against unauthorized access

Recommended configuration for fermentation

For precision dosing in a biotechnological process, the optimal combination is: D-type (Δ) sensor DN01–DN02 for micro-flow of pH adjusters and antifoams + L-type (straight-tube) DN08–DN15 for nutrient media and substrates + mirror polishing Ra ≤ 0.8 µm + Tri-clamp connections + ME400 transmitter with Modbus for integration into the bioreactor control system. 0.1% accuracy ensures strict adherence to fermentation parameters with minimal losses of expensive components.

Key parameters

Mass-EXPERT technical capabilities for biotechnology

Liquid mass flow: from 0.1 to 18,000 kg/h
Measurement accuracy: ±0.1% – ±0.2%
Repeatability: ±0.05%
Medium temperature: from –50 to +350 °C
D-type (Δ) sensor: DN01–DN02, from 0.1 kg/h
L-type (straight-tube) sensor: DN08–DN50
Surface roughness: Ra ≤ 0.8 µm
SIP compatibility
Hygienic connections: Tri-clamp
Hygienic design: to 3-A Sanitary Standards requirements
Output signals: 4–20 mA HART, Modbus RTU/RS-485
Ingress protection: IP66/IP67, stainless steel
Specification

Mass-EXPERT biotech sensors

Summary table of D-type (Δ) and L-type (straight-tube) sensor sizes recommended for biotechnology and Life Sciences.

Sensor model Type DN Flow range (kg/h) Max. pressure (MPa) Applications
D-01 Δ-shaped DN01 0.1 – 12 25 pH adjusters, antifoams
D-02 Δ-shaped DN02 up to 96 25 Micro-dosing of reagents
L-08 Straight-tube DN08 1 – 1 200 10 Nutrient media, substrates
L-15 Straight-tube DN15 2 – 3 600 10 Nutrient media, additives
L-25 Straight-tube DN25 10 – 12 000 10 Main flows in fermenters

U- and W-type sensors are also available for specific tasks — selected individually.

FAQ

Frequently asked questions

Answers to the questions most often asked about this application.

Columns:

690 questions across 23 applications — in the FAQ Center

Related applications

Where else Mass-EXPERT flow meters are used

Ready to discuss your task?

We will select the optimal Mass-EXPERT configuration for your facility.

Select the flow meter yourself Product home
Наверх