Design G is intended for flow measurement of high-temperature media. The operating temperature range is from −50 °C to +230 °C. Hot oils, melts, superheated steam — design G maintains accuracy and stability under the harshest conditions. Available in a remote (separate) design to protect the electronics from overheating.

Technical specifications Request a quote
−50 °C … +230 °C Hot oils Melts Superheated steam Remote (separate) design
Overview

G — High temperature

Design G is engineered for applications requiring reliable flow measurement at extreme temperatures. Special heat-resistant materials and construction ensure long-term reading stability in media with temperatures from −50 °C to +230 °C.

−50 … +230
°C temperature range
Remote
Design (electronics remote-mounted)
Steam / Oils
Hot media
Melts
Polymers, bitumen, sulfur

Key features

Wide temperature range — from −50 °C to +230 °C for operation with a wide variety of media
Remote (separate) design — the transmitter is remote-mounted outside the hot zone to protect it from overheating
Hot oils and melts — special heat-resistant seals and wetted-part materials
Superheated steam — stable measurement at high steam temperatures without loss of accuracy
Thermal cycling resistance — the design withstands repeated heating/cooling cycles

Recommended applications

Hot oils and heat transfer media Chemical industry Superheated steam Polymer melts Bitumen and asphalt mixes Molten sulfur Oil refining
Technical specifications

Design G specifications

Key performance characteristics of the G high-temperature design

Parameter Value
Medium temperature range from −50 °C to +230 °C
Operating pressure up to 10 MPa
Sizes DN01–DN250 (dimensions same as design T)
Mass measurement accuracy (liquid) from ±0.1%
Mass measurement accuracy (gas) ±0.5–1.0%
Design Remote (electronics unit remote-mounted)
Wetted-part materials Stainless steel 316L / Hastelloy (optional)
Applicable media Hot oils, melts, superheated steam, heat transfer media

* Specific values depend on the size, seal material and operating conditions. Please confirm at the time of order depending on the process medium and temperature.

Design

Remote (separate) design

To protect the electronics from high-temperature exposure

Configuration
Remote

The transmitter and the electronics unit are mounted separately

Interconnect cable
Shielded

Special cable between the sensor and the electronics

Advantage
Reliability

The electronics are protected from overheating, extending the service life of the meter

Applications

Where it is used